Loading
  • Link to LinkedIn
  • Home
  • Careers
  • Contact
CTDG - Convergent Technologies Design Group, Inc.
  • About Us
    • Our Story
    • Our Process
    • Featured Projects
    • Testimonials
    • Careers
  • Markets
    • Business Schools
    • Commercial
    • Courtrooms & Law Schools
    • Data Centers
    • Emergency Operations & Public Safety
    • Environments for Aging
    • Federal Government
    • Financial & Banking
    • Healthcare
    • Higher Education
    • Hospitality & Gaming
    • Houses of Worship
    • K-12
    • LEED Certified Projects
    • Libraries
    • Mixed-Use Residential
    • Museums & Cultural Centers
    • Proton Facilities
    • Radio, TV & Recording Studios
    • Recreation & Wellness
    • Schools of Health & Medicine
    • Science & Technology
    • Theaters & Performing Arts Venues
  • Services
    • Acoustics, Noise & Vibration Control
    • Audiovisual Planning & Multimedia Systems
    • Electronic Security Systems
    • Healthcare Low Voltage Systems Design
    • Telecommunications Cabling Systems
    • Theatrical Lighting Design
  • Our Work
    • Ruth Bader Ginsburg Hospital
    • Georgetown University Law Center, Hart Auditorium (McDonough Hall)
    • Duquesne University – College of Osteopathic Medicine
    • MGM Resorts International, National Harbor
    • George Mason University – Horizon Hall
    • National Institutes of Health (NIH) Building 10
    • US Department of Energy, NREL Laboratory
    • Virginia Commonwealth University, Children’s Hospital
  • News
  • Education
  • Menu Menu
Business Schools, Data Centers, Higher Education, Projects, Telecommunications

Virginia Western Community College – Business Sciences Building

University of Virginia, Western – Systems by CTDG

[col3]The scope of this project included reviewing the existing Data Center design to evaluate pros and cons of relocation/ replacement versus modification. In addition to the Data Center assessment, an analysis on the impact of Data Center renovation or replacement on VWCC campus, network operations and other buildings on campus, associated telecommunications cabling system and infrastructure, and associated power and cooling systems was also conducted. The Data Center’s current location occurred as a result of the evolution of the campus network over many years, proving the location was functional but not necessarily planned.Taking into consideration the extensive amount of cabling and network electronics located in the data center, it was decided prudent to maintain and utilize the existing location.The presence of newly installed power facilities and an existing cooling system also made the decision to keep the data center racks and equipment where they were currently located the most practical and economically sound decision.  It was also determined that the re-design effort, as it related to the Data Center, needed to address numerous points: power requirements of existing and potential future electronics; cooling and environmental control capabilities (temperature and humidity); access control; and adequate room for growth. It was concluded that as a result of the redesign of the second floor, the telecommunications cabling system would be impacted significantly. Specific cabling systems such as the outside plant copper, fiber and coaxial backbone (OSP), internal backbone copper, fiber and coaxial backbone (Riser), and the above ceiling structured cabling system (Horizontal), at the time, connected existing campus buildings, and had to be protected during redesign. Damage received to any of those named systems could have resulted in outages, or loss of service to the classrooms and lab connections. Many of these cables needed to be removed and replaced in the proposed areas of redesign while others remained connected to their existing outlet locations. Close coordination between departments located in these construction affected areas and the re-design team was necessary to ensure that unscheduled outages did not take place. This project has been successfully completed since 2008.[/col3]

[col3]Architect: SFCS, Inc.
Location: Roanoke, Virginia
Construction Cost:
 $2 Million
Project Size: 20,000 gsf[/col3]

Share this entry
  • Share on LinkedIn
  • Share by Mail
https://ctdginc.com/wp-content/uploads/2018/05/Uof-Virginia-Western.jpg 414 640 admin https://ctdginc.com/wp-content/uploads/2024/06/Convergent-Technologies-Design-Group-Logo_340x156px-72dpi_Green-and-Black-Logo.png admin2018-05-14 15:25:162024-12-31 08:59:16Virginia Western Community College – Business Sciences Building

Recent Posts

  • Outstanding Design Award!
  • Outdoor Audiovisual System Solutions at Eastern Carolina University
  • Project Spotlight: The Zayed Bloomberg Building Underwent a Major Upgrade for Next-Gen Healthcare
  • Project Spotlight: Grand Opening of the New Stockton University Residence Hall
  • Project Spotlight: USDA Forage-Animal Production Research Unit at the University of Kentucky

Categories

  • Acoustics
  • Audiovisual
  • Award Received
  • Business Schools
  • Court Rooms and Law Schools
  • Cultural
  • Data Centers
  • Emergency Operations
  • Federal
  • Healthcare
  • Higher Education
  • Hospitality
  • Hospitality and Gaming
  • HVAC
  • K-12
  • LEED
  • Libraries
  • Lighting
  • low voltage healthcare
  • Markets
  • Municipal
  • Museums
  • News
  • Projects
  • proton
  • Proton Center
  • Public Safety
  • Radio TV and Recording Studios
  • rec and wellness
  • Schools of Health
  • Science and Technology
  • Security
  • Telecommunications
  • Theaters and Performing Arts
  • Uncategorized

ARIZONA
4651 South Lakeshore Drive
Tempe, Arizona 85282
v: 480.345.9951
f: 480.345.9952

NEW YORK
448 W 37th Street, 7D
New York , New York 10018
v: 646.475.5116
f: 646.475.5117

MARYLAND
6501 York Road
Baltimore, MD 21212
v: 410.532.2395
f: 410.532.2396

ARIZONA
4651 South Lakeshore Drive
Tempe, Arizona 85282
v: 480.345.9951
f: 480.345.9952

NEW YORK
448 W 37th Street, 7D
New York , New York 10018
v: 646.475.5116
f: 646.475.5117

MARYLAND
6501 York Road
Baltimore, MD 21212
v: 410.532.2395
f: 410.532.2396

©2025 Convergent Technologies Design Group, Inc. All rights reserved.

Site designed by Mostyn Marketing Group / Built Creative.   |   Privacy Policy   |   Terms of Use   |   Site Map

  • Link to LinkedIn

©2025 Convergent Technologies Design Group, Inc. All rights reserved.

Site designed by Mostyn Marketing Group / Built Creative.

Privacy Policy   |   Terms of Use   |   Site Map

  • Link to LinkedIn

Scroll to top Scroll to top Scroll to top